Logo image
Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
Journal article   Open access   Peer reviewed

Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion

J Quek, S G Brauer, J Treleaven, Yong-Hao Pua, Benjamin Mentiplay and Ross Clark
Journal of NeuroEngineering and Rehabilitation, Vol.11, 65
2014
pdf
PDF - Published Version (Open Access)505.49 kBDownloadView
Published VersionPDF - Published Version (Open Access)CCBY_V2.0 Open Access
url
https://doi.org/10.1186/1743-0003-11-65View
Published Version

Abstract

spine whiplash inertial monitoring unit phone cervical range of motion
Background: Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Findings. Twenty-one healthy individuals (age:31±9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. Conclusion: The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine. © 2014 Quek et al.; licensee BioMed Central Ltd.

Details

Metrics

20 File views/ downloads
369 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Web Of Science research areas
Engineering, Biomedical
Neurosciences
Rehabilitation

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Logo image