Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: A reliability and validity study
Journal article   Open access   Peer reviewed

Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: A reliability and validity study

Benjamin Mentiplay, L G Perraton, Kelly Bower, B Adair, Yong-Hao Pua, G P Williams, R McGaw and Ross Clark
PLoS One, Vol.10(10), e0140822
2015
pdf
PDF - Published Version (Open Access)750.44 kBDownloadView
Published VersionPDF - Published Version (Open Access)CC BY V4.0 Open Access
url
https://doi.org/10.1371/journal.pone.0140822View
Published Version

Abstract

Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference Kin-Com dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ô 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ô 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31-0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. © 2015 Mentiplay et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Details

Metrics

200 File views/ downloads
452 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Highly Cited Paper 
Collaboration types
Domestic collaboration
International collaboration
Web Of Science research areas
Sport Sciences
Logo image