Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants
Journal article   Peer reviewed

Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants

B Ficial, A E Finnemore, D J Cox, Kathryn Broadhouse, A N Price, G Durighel, G Ekitzidou, J V Hajnal, A D Edwards and A M Groves
Journal of the American Society of Echocardiography, Vol.26(12), pp.1365-1371
2013
url
https://doi.org/10.1016/j.echo.2013.08.019View
Published Version

Abstract

echocardiography phase-contrast MRI preterm infants
Background The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants. Methods Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants. Results Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43-40 weeks) and a median weight at scan of 1,880 g (range, 660-3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment (R2 = 0.83; mean bias, -9.6 mL/kg/min; limits of agreement, -79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment (R2 = 0.22; mean bias, -13.7 mL/kg/min; limits of agreement, -89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI (R2 = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, -53.4 to +58.6 mL/kg/min; repeatability index, 54.5%). Conclusions Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.

Details

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Web Of Science research areas
Cardiac & Cardiovascular Systems

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Logo image