Journal article
Seismic retrofit of gravity retaining walls for residential fills using ground anchors
Geotechnical and Geological Engineering, Vol.25(6), pp.679-691
2007
Abstract
Failure of several gravity retaining walls in residential areas built on reclaimed land, during the October 23, 2004 Chuetsu earthquake in Niigata Prefecture, Japan, determined the authorities to consider the seismic retrofit of the walls in order to mitigate future similar disasters in the urban environment. This study addresses the effectiveness of ground anchors in improving the seismic performance of such retaining structures through a sliding block analysis of the seismic response of an anchored gravity retaining wall supporting a dry homogeneous fill slope subject to horizontal ground shaking. Sliding failure along the base of the wall and translational failure along a planar slip surface of the active wedge within the fill material behind the wall were considered in the formulation, whereas the anchor load was taken as a line load acting on the face of the gravity retaining wall. The effects of magnitude and orientation of anchor load on the yield acceleration of the wall-backfill system and seismically induced wall displacements were examined. It was found that for the same anchor orientation, the yield acceleration increases in a quasi-linear manner with increasing the anchor load, whereas an anchor load of a given magnitude acting at various orientations produces essentially identical yield accelerations. On the other hand, the computed earthquake-induced permanent displacements of the anchored gravity retaining wall decrease exponentially with increasing magnitude of anchor load. Additionally, the influence of backfill strength properties (e.g., internal friction angle) on the seismic wall displacement appears to diminish considerably for the anchored gravity retaining wall. A dynamic displacement analysis conducted for the anchored gravity retaining wall subjected to various seismic waveforms scaled to the same peak earthquake acceleration revealed a good correlation between the calculated permanent wall displacements and the Arias intensity parameter characterizing the input accelerogram. © Springer Science+Business Media B.V. 2007.
Details
- Title
- Seismic retrofit of gravity retaining walls for residential fills using ground anchors
- Authors
- A C Trandafir (Author) - University of Utah, United StatesT Kamai (Author) - Kyoto University, JapanRoy C Sidle (Author) - Kyoto UniversityM Popescu (Author) - Illinois Institute of Technology, United States
- Publication details
- Geotechnical and Geological Engineering, Vol.25(6), pp.679-691
- Publisher
- Springer Netherlands
- Date published
- 2007
- DOI
- 10.1007/s10706-007-9140-9
- ISSN
- 0960-3182
- Organisation Unit
- University of the Sunshine Coast, Queensland; Sustainability Research Cluster
- Language
- English
- Record Identifier
- 99449941402621
- Output Type
- Journal article
Metrics
583 Record Views
InCites Highlights
These are selected metrics from InCites Benchmarking & Analytics tool, related to this output
- Collaboration types
- Domestic collaboration
- International collaboration
- Web Of Science research areas
- Engineering, Geological
UN Sustainable Development Goals (SDGs)
This output has contributed to the advancement of the following goals:
Source: InCites