Logo image
Prostate cancer GTV delineation with biparametric MRI and 68Ga-PSMA-PET: comparison of expert contours and semi-automated methods
Journal article   Peer reviewed

Prostate cancer GTV delineation with biparametric MRI and 68Ga-PSMA-PET: comparison of expert contours and semi-automated methods

Nathan Hearn, John Blazak, Philip Vivian, Dinesh Vignarajah, Katelyn Cahill, Daisy Atwell, Jim Lagopoulos and Myo Min
British Journal of Radiology, Vol.94(1119), pp.1-11
2021
PMCID: PMC8011238
PMID: 33507812
url
https://doi.org/10.1259/bjr.20201174View
Published Version

Abstract

Other Collaborations Thompson Institute Special Collection
OBJECTIVE: The optimal method for delineation of dominant intraprostatic lesions (DIL) for targeted radiotherapy dose escalation is unclear. This study evaluated interobserver and intermodality variability of delineations on biparametric MRI (bpMRI), consisting of T2 weighted (T2W) and diffusion-weighted (DWI) sequences, and 68Ga-PSMA-PET/CT; and compared manually delineated GTV contours with semi-automated segmentations based on quantitative thresholding of intraprostatic apparent diffusion coefficient (ADC) and standardised uptake values (SUV). METHODS: 16 patients who had bpMRI and PSMA-PET scanning performed prior to any treatment were eligible for inclusion. Four observers (two radiation oncologists, two radiologists) manually delineated the DIL on: (1) bpMRI (GTVMRI), (2) PSMA-PET (GTVPSMA) and (3) co-registered bpMRI/PSMA-PET (GTVFused) in separate sittings. Interobserver, intermodality and semi-automated comparisons were evaluated against consensus Simultaneous Truth and Performance Level Estimation (STAPLE) volumes, created from the relevant manual delineations of all observers with equal weighting. Comparisons included the Dice Similarity Coefficient (DSC), mean distance to agreement (MDA) and other metrics. RESULTS: Interobserver agreement was significantly higher (p < 0.05) for GTVPSMA (DSC: 0.822, MDA: 1.12 mm) and GTVFused (DSC: 0.787, MDA: 1.34 mm) than for GTVMRI (DSC: 0.705, MDA 2.44 mm). Intermodality agreement between GTVMRI and GTVPSMA was low (DSC: 0.440, MDA: 4.64 mm). Agreement between semi-automated volumes and consensus GTV was low for MRI (DSC: 0.370, MDA: 8.16 mm) and significantly higher for PSMA-PET (0.571, MDA: 4.45 mm, p < 0.05). CONCLUSION: 68Ga-PSMA-PET appears to improve interobserver consistency of DIL localisation vs bpMRI and may be more viable for simple quantitative delineation approaches; however, more sophisticated approaches to semi-automatic delineation factoring for patient- and disease-related heterogeneity are likely required. ADVANCES IN KNOWLEDGE: This is the first study to evaluate the interobserver variability of prostate GTV delineations with co-registered bpMRI and 68Ga-PSMA-PET.

Details

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Industry collaboration
Domestic collaboration
Web Of Science research areas
Radiology, Nuclear Medicine & Medical Imaging

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: SDGs from InCites

Logo image