Logo image
Preliminary study of microbiologically influenced corrosion by Pseudomonas aeruginosa on high Chromium white iron
Journal article   Open access   Peer reviewed

Preliminary study of microbiologically influenced corrosion by Pseudomonas aeruginosa on high Chromium white iron

Cedric Tan, Naveen Elumalai and Kannoorpatti Krishnan
PLoS One, Vol.19(8), pp.1-21
2024
PMID: 39163379
pdf
journal.pone.03061643.14 MBDownloadView
Published Version Open Access CC BY V4.0
url
https://doi.org/10.1371/journal.pone.0306164View
Published Version Open CC BY V4.0

Abstract

Corrosion High Chromium White Iron (HCWI) Microbiologically Influenced Corrosion (MIC) Pseudomonas aeruginosa (P. Aeruginosa) economic losses safety hazards microbial corrosion
Microbiologically Influenced Corrosion (MIC) poses a significant challenge to various industries, leading to substantial economic losses and potential safety hazards. Despite extensive research on the MIC resistance of various materials, there is a lack of studies focusing on High Chromium White Iron (HCWI) alloys, which are widely used in wear-resistant applications. This study addresses this knowledge gap by providing a comprehensive investigation of the MIC resistance of three HCWI alloys with varying chromium contents (22 wt%, 30.7 wt%, and 21 wt%) in the presence of Pseudomonas aeruginosa (P. Aeruginosa), a common bacterial species associated with MIC. The alloys were exposed to an artificial seawater medium inoculated with P.Aeruginosa for 14 days, and their corrosion behaviour was evaluated using electrochemical techniques, surface analysis, and microscopy. Electrochemical Impedance Spectroscopy (EIS) results revealed that the alloy with the highest chromium content (A2, 30.7 wt% Cr) exhibited superior MIC resistance compared to the other alloys (A1, 22 wt% Cr and M1, 21 wt% Cr). The enhanced performance of alloy A2 was attributed to the formation of a more stable and protective passive film, as well as the development of a more compact and less permeable biofilm. The EIS data, interpreted using equivalent circuit models, showed that alloy A2 had the highest charge transfer resistance and the lowest biofilm capacitance, indicating a more effective barrier against corrosive species. Bode plots further confirmed the superior corrosion resistance of alloy A2, with higher impedance values and phase angles at low frequencies compared to alloys A1 and M1. Scanning Electron Microscopy (SEM) and optical microscopy analyses corroborated these findings, showing that alloy A2 had the lowest pit density and size after 14 days of exposure. The insights gained from this study highlight the critical role of chromium content in the MIC resistance of HCWI alloys and have significant implications for the design and selection of materials for applications prone to microbial corrosion.

Details

Metrics

1 Record Views
Logo image