Peripheral intravenous catheter duration and failure in paediatric acute care: A prospective cohort study
Journal article   Peer reviewed

Peripheral intravenous catheter duration and failure in paediatric acute care: A prospective cohort study

Lorelle Malyon, Amanda J Ullman, Natalie Phillips, Jeanine Young, Tricia Kleidon, Jenny Murfield and Claire M Rickard
Emergency Medicine Australasia, Vol.26(6), pp.602-608
2014
url
https://doi.org/10.1111/1742-6723.12305View
Published Version

Abstract

clinical audit emergency medicine medical device failure paediatric peripheral venous catheterisation securement practice
Objective: Children admitted to hospital commonly require peripheral intravenous catheters (PIVCs) for treatment. This study sought to address a gap in the literature about current practice in the securement and dressing of PIVCs in paediatric acute care, and to ascertain the duration and failure of these devices. Methods: A prospective cohort study conducted at the Royal Children's Hospital in Queensland, Australia. All patients aged 0-15 years, who presented to the ED between 16 July and 16 October 2012, and had a PIVC inserted prior to emergent admission to the hospital were included. Results: Of 458 participants, median device duration was 29 h (IQR 13- 58 h), and ranged from less than 1 h to 16 days. One quarter (113/456, 24.8%) of PIVCs were removed due to device failure, presenting as: infiltration (65/456, 14.3%); accidental dislodgement (23/456, 5.0%); blockage (12/456, 2.6%); phlebitis (7/456, 1.5%); or 'other' (6/456, 1.3%). PIVC securement and dressings were predominantly bordered polyurethane dressings and splints (n = 457/458, 99.8%). PIVC placement in the antecubital fossa, in comparison to the hand, was significantly associated with an increased risk for failure (P = 0.03). No other patient and device characteristics had a significant association with device failure (P > 0.05). The median dwell time of PIVCs that failed was significantly longer than the PIVCs that did not fail (44.0 vs 25.5 h; P = 0.002). Less than half (53/113, 46.9%) of failed catheters were replaced with a new PIVC. Conclusions: Observed failure rates were high for a clinically essential device; however, there is no established rate of acceptability against which the results can be benchmarked against to facilitate effectiveness of practice. Many PIVCs appeared to remain in place longer than needed. Dressing and securement practice was homogenous. PIVC placement in the antecubital fossa should be minimised to reduce the risk of paediatric PIVC failure.

Details

Metrics

20 File views/ downloads
867 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Web Of Science research areas
Emergency Medicine

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Logo image