Effect of the material's stiffness on stress-shielding in osseointegrated implants for boneanchored prostheses: a numerical analysis and initial benchmark data
Journal article   Peer reviewed

Effect of the material's stiffness on stress-shielding in osseointegrated implants for boneanchored prostheses: a numerical analysis and initial benchmark data

Piotr Prochor, Laurent Frossard and Sajewicz Eugeniusz
Acta of Bioengineering & Biomechanics, Vol.22(2), pp.1-24
2020
url
https://doi.org/10.37190/ABB-01543-2020-02View
Published Version

Abstract

Biomedical Engineering Clinical Sciences Human Movement and Sports Science bone mass bone remodelling boneanchored prosthesis osseointegration Young's modulus
Purpose: This study attempted to establish the link between design of implants for boneanchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract datasets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity. Methods: We considered three designs: threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young's modulus (10 GPa to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 mm to 18 mm) and thickness of medullar part (5 mm to 1 mm) was investigated for the modular press-fit implant. Results: The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass 5% lower to press-fit design. The influence of Young's modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively. Conclusions: Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.

Details

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Web Of Science research areas
Biophysics
Engineering, Biomedical

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites