Geomatic Engineering spectroradiometer ultraviolet
The fifth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 13 to 21, 2003 at Table Mountain outside of Boulder, Colorado, USA. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NOAA and included participants from six national and international agencies. The UV measuring instruments included scanning spectroradiometers, spectrographs, and multi-filter radiometers. Synchronized spectral scans of the solar irradiance were performed between June 16 and 20, 2003. The spectral responsivities were determined for each instrument using the participants' lamps and calibration procedures and with NOAA/CUCF standard lamps. This paper covers the scanning spectroradiometers and the one spectrograph. The solar irradiance measurements from the different instruments were deconvolved using a high resolution extraterrestrial solar irradiance and reconvolved with a 1-nm triangular band-pass to account for differences in the bandwidths of the instruments. The measured solar irradiance from the spectroradiometers using the rivmSHIC algorithm on a clear-sky day on DOY 172 at 17.0 UTC (SZA = 30o) had a relative 1-σ standard deviation of +/-2.6 to 3.4% for 300- to 360-nm using the participants' calibration. © 2008 Society of Photo-Optical Instrumentation Engineers.

Details

Metrics

32 File views/ downloads
2656 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Web Of Science research areas
Environmental Sciences
Imaging Science & Photographic Technology
Remote Sensing

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#13 Climate Action

Source: InCites

Logo image