Logo image
Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: A proof-of-concept study
Journal article   Peer reviewed

Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: A proof-of-concept study

Laurent Frossard, D L Gow, K Hagberg, N Cairns, B Contoyannis, Steven Gray, R Brånemark and M Pearcy
Gait & Posture, Vol.31(2), pp.223-228
2010
url
https://doi.org/10.1016/j.gaitpost.2009.10.010View
Published Version

Abstract

rehabilitation lower limb amputation osseointegration load bearing force sensor
The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by four-fold anteriorly and 14-fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by nine-fold laterally and 16-fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17% and 83% of the trials, respectively, by up to ±10%. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs. © 2009 Elsevier B.V.

Details

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Web Of Science research areas
Neurosciences
Orthopedics
Sport Sciences

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Logo image