Journal article
The use of hand-carried ultrasound in the hospital setting-A cost-effective analysis
Journal of the American Society of Echocardiography, Vol.18(6), pp.620-625
2005
Abstract
Objectives: We sought to assess the accuracy of hand-carried ultrasound (HCU) in the prediction of a normal study, and its cost-effectiveness in reducing the number of standard departmental echocardiograms (SDE) performed on hospital inpatients. Objectives: The setting was a district general hospital. Participants were 157 consecutive inpatients, mean age 68 (range: 18-97) years, 95 men (61%), referred for SDE. HCU was performed at the bedside as part of the clinical assessment. SDE was performed routinely. Main outcome measures were: (1) assessment of the accuracy of HCU in detection of a normal or abnormal study as determined by SDE; and (2) a cost-effectiveness analysis. Results: Indications for echocardiography were: left ventricular (LV) function assessment, n = 101 (64.3%); valvular abnormalities, n = 11 (7%); arrhythmia, n = 4 (2.6%); miscellaneous, n = 10 (6.4%); and no reason stated, 31 (19.7%). The sensitivity, specificity, and positive and negative predictive values of HCU predicting a completely normal scan were 74%, 96%, 94%, and 81%, respectively, and of predicting normal LV function in requests specific for LV function assessment were 81%, 100%, 100%, and 77%, respectively. If either all inpatients or those with requests for LV function assessment underwent HCU initially, and only those with abnormal scans underwent further SDE, there would be a 29% and 22% reduction in departmental workload and a cost saving of £23,000 and £30,000, respectively. Conclusion: HCU is an accurate method of identifying patients with normal hearts as determined by SDE. Its routine use is cost-effective and can significantly reduce the number of SDE that need be performed. Copyright © 2005 by the American Society of Echocardiography.
Details
- Title
- The use of hand-carried ultrasound in the hospital setting-A cost-effective analysis
- Authors
- Kim Greaves (Author) - Northwick Park Hospital, United KingdomP Jeetley (Author) - Northwick Park Hospital, United KingdomM Hickman (Author) - Northwick Park Hospital, United KingdomG Dwivedi (Author) - Northwick Park Hospital, United KingdomN Sabharwal (Author) - Northwick Park Hospital, United KingdomT Lim (Author) - Northwick Park Hospital, United KingdomR Janardhanan (Author) - Northwick Park Hospital, United KingdomR Senior (Author) - Northwick Park Hospital, United Kingdom
- Publication details
- Journal of the American Society of Echocardiography, Vol.18(6), pp.620-625
- Publisher
- Mosby, Inc.
- Date published
- 2005
- DOI
- 10.1016/j.echo.2004.09.015
- ISSN
- 0894-7317; 0894-7317
- Organisation Unit
- Faculty of Science, Health, Education and Engineering; University of the Sunshine Coast, Queensland
- Language
- English
- Record Identifier
- 99449195802621
- Output Type
- Journal article
Metrics
353 Record Views
InCites Highlights
These are selected metrics from InCites Benchmarking & Analytics tool, related to this output
- Web Of Science research areas
- Cardiac & Cardiovascular Systems
UN Sustainable Development Goals (SDGs)
This output has contributed to the advancement of the following goals:
Source: InCites